How to Zero and Span the SOR 815DT Smart Differential Pressure Transmitter

SOR 815DTThe SOR 815DT smart differential pressure transmitter is a rugged, compact, light weight, loop powered instrument that is ideally suited for hazardous locations and hostile environments where space is limited. The 815DT offers many industry standard outputs to meet applications where low cost, discrete and continuous monitoring is required or preferred. This versatile instrument may be used to reliably measure differential pressure, level or flow.

Zero and Span
  1. The 815DT has the ability to easily set the zero and span set points with a magnet externally.
  2. Located on the casting is a circle for zero and a triangle for span.
  3. To set the zero, bring the pressure to the desired value, and touch the magnet to the circle for 3 seconds.
  4. This will set the current pressure to zero.
  5. This is the same process for setting the span.
  6. Also, by holding the magnet to the circle and triangle at the same time, you will enter a test mode.
Instrument Specialties, Inc.
http://isi.group
407-324-7800

Applying Electric Valve Actuators: Needs Assessment

Electric valve actuator
Electric valve actuator (AUMA)
Electric actuators can be found in all varieties of shapes and sizes in waste water treatment plants.  Since the valves to be automated vary in both design and dimension, size consideration and design through an early "needs assessment" is a critical component of the specification process.

Defined as an explicit set of requirements to be satisfied by a material, product, or service, engineers, during this step, will specify what the solution will accomplish, without describing how it will do it.  Specifications usually originate from either design constraints or functional requirements.

As part of the spec requirements and need assessment, these are a number of the questions that engineers should consider, as early in the process as possible, in assessing the needs for a valve actuator.
  1. What sort of valve will be needed?  Does the process require linear control valves or rotary quarter turn valves?  This will define the appropriate type of actuator, as well.
  2. What is the specification for the actuator sizing? The size will need to match the needed thrust and torque as well as the type of valve.  The efficient actuator, to ensure good valve control, can be neither oversized nor undersized.
  3. What are the power requirements, e.g. how much energy will be needed to run the actuator?  Higher voltage actuators use more energy. Low power requirements mean that backup power is more economical.  In most settings, there is a need to save money by running as efficiently as possible, and there are also environmental sustainability hurdles. 
  4. Operating Conditions:  Is there severe weather or will the actuator be under water? What is the range of temperatures expected? Keep in mind that not all actuators can work in all conditions.
  5. Will the actuator need to run continuously or intermittently? Consider the variation needed in the process. Actuators that have continual modulation are more able to respond to variations in the control requests.
  6. Consideration of environmental safety conditions.  What about dust or explosive gases?
Ultimately, the needs assessment will help guide the specification process, with the goal of ensuring how well the final product will perform.  It will pay off to be as detailed as possible during this phase.  Once a needs assessment is finalized, you will be in a better position to specify the right actuator to meet your process requirements.

For more information on specifying electric valve actuators, contact Instrument Specialties by calling 407-324-7800 or visit their web site at http://isi.group

Temperature Sensors from SOR

Temperature Sensors from SOR
SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty temperature sensors.

All RTDs are 100% tested to insure that the accuracy and the continuity of the product have not been affected by the manufacturing process. The standard sheath material on all RTDs specified in this section is 316SS. Other sheath materials and coatings are available.

All industrial thermocouples are manufactured using a high purity mineral oxide insulation and a metallic sheath. The standard sheath material unless otherwise noted is 316SS.

Review the embedded catalog below, or download you own SOR Temperature Sensor Catalog from this link.

High Velocity Flow Monitoring in a Sanitary Sewer

View of flow inside the pipe
View of flow inside the pipe.
A sanitary sewer within a local municipality had two options for flow monitoring applications. The first application was in front of an overflow bypass gate where standard area velocity flow monitoring technologies were installed and working, but only intermittently. When the gate closed, the water surcharged the pipe until it overflowed into the bypass weir. The AV sensor was no longer able to read the bypass flow because the water at the bottom of the channel was no longer flowing. Another challenge was with the pipe joints creating turbulence.

The alternate flow monitoring location was upstream, in a 42 inch pipe, and on the side of a hill. The level, which is 1-3 inches deep with velocity of 4.5 ft/s, was an additional challenge. Standard in-pipe area velocity sensors are not able to operate in conditions where high velocity effects the depth of the water accelerating over the top of the sensor (Bernoulli Effect) resulting in lower recorded levels.
Chart of the sensors output
Chart of the sensors output (click for larger view)

The solution in this application was LaserFlow. LaserFlow uses a non-contact sensor that utilizes a non-contact ultrasonic level sensor and a laser to read the velocity below the surface. In this application the LaserFlow allowed for accurate readings to be taken even in the most turbulent of flows.

After the initial setup the LaserFlow sensor worked well for several hours. When the level decreased, the laser started to focus on the bottom of the channel due to the steep slope of the pipe. There were two options to correct this issue:
Flow Meter technician in the pipe adjusting the LaserFlow
Flow Meter technician in the pipe
adjusting the LaserFlow.
  • Send a technician back into the confined space to position the LaserFlow sensor parallel with the flow stream. 
  • Change the slope programming setting to match the slope of the pipe without having to enter into the confined space.
It was decided the slope setting would be changed. After determining the slope of the pipe from a 12 foot rise over a 150 foot run =8% slope. After a few program adjustments, the sensor worked flawlessly.


For more information about the Teledyne ISCO LaserFlow, contact Instrument Specialties, Inc. by visiting http://isi.group or by calling 407-324-7800.

AUMA Electric Actuators Models SA and SQ: Setting the Limit Switches

This video below explains how to set the internal limit switches on the AUMA SA and SQ electric actuators.

AUMA is the world's leading manufacturer of electric actuators and gearboxes.
  • SA type actuators - range for open-close duty and positioning duty are rated for class A and B or types of duty S2 - 15 min. A special version for longer running is available for the S2 - 30 min duty.
  • The modulating actuators of the SAR range are rated for class C or types of duty S4 - 25 %. Special versions for S4 - 50 % and S5 - 25 % are also available.
  • SQ type actuators - range for open-close duty and positioning duty are rated for class A and B or types of duty S2 - 15 min. 
  • The modulating actuators of the SQR range are rated for class C or types of duty S4 - 25 %.
http://isi.group
407-324-7800

Instrument Specialties Inc. Appointed New Exclusive Rep for AUMA Actuators in South Florida Municipal Market

AUMA, the world's leading manufacturer of electric actuators and gearboxes has appointed Instrument Specialties Inc. (ISI) as exclusive rep for the South Florida municipal (water) market. AUMA distinguishes the municipal market as sewage treatment plants, water treatment plants, drinking water distribution, sewage disposal, seawater desalination and steel constructions for water systems to operate weirs and sluice gates.
AUMA actuators are ubiquitous in the water industry due to their broad product offering which includes multi-turn, part-turn, and linear actuators, combined with a robust design that includes high corrosion protection, long service life, and low maintenance.

For more information, call 407-324-7800 of visit http://isi.group.