SOR manufactures a complete line of thermocouple elements, Resistance Temperature Detector (RTD) sensors, thermowells, industrial assemblies and specialty temperature sensors.
All RTDs are 100% tested to insure that the accuracy and the continuity of the product have not been affected by the manufacturing process. The standard sheath material on all RTDs specified in this section is 316SS. Other sheath materials and coatings are available.
All industrial thermocouples are manufactured using a high purity mineral oxide insulation and a metallic sheath. The standard sheath material unless otherwise noted is 316SS.
Review the embedded catalog below, or download you own SOR Temperature Sensor Catalog from this link.
An informational site dedicated to process control education. Posts on this blog contain interesting and noteworthy information about process instrumentation, valves, and equipment used in industrial and municipal facilities. This blog is sponsored by Instrument Specialties, Inc. (ISI). For more information, please visit ISI.GROUP
High Velocity Flow Monitoring in a Sanitary Sewer
![]() |
View of flow inside the pipe. |
The alternate flow monitoring location was upstream, in a 42 inch pipe, and on the side of a hill. The level, which is 1-3 inches deep with velocity of 4.5 ft/s, was an additional challenge. Standard in-pipe area velocity sensors are not able to operate in conditions where high velocity effects the depth of the water accelerating over the top of the sensor (Bernoulli Effect) resulting in lower recorded levels.
![]() |
Chart of the sensors output (click for larger view) |
The solution in this application was LaserFlow. LaserFlow uses a non-contact sensor that utilizes a non-contact ultrasonic level sensor and a laser to read the velocity below the surface. In this application the LaserFlow allowed for accurate readings to be taken even in the most turbulent of flows.
After the initial setup the LaserFlow sensor worked well for several hours. When the level decreased, the laser started to focus on the bottom of the channel due to the steep slope of the pipe. There were two options to correct this issue:
![]() |
Flow Meter technician in the pipe adjusting the LaserFlow. |
- Send a technician back into the confined space to position the LaserFlow sensor parallel with the flow stream.
- Change the slope programming setting to match the slope of the pipe without having to enter into the confined space.
For more information about the Teledyne ISCO LaserFlow, contact Instrument Specialties, Inc. by visiting http://isi.group or by calling 407-324-7800.
Labels:
Florida,
flow measurement,
ISCO,
LaserFlow,
open channel,
Teledyne ISCO
AUMA Electric Actuators Models SA and SQ: Setting the Limit Switches

AUMA is the world's leading manufacturer of electric actuators and gearboxes.
- SA type actuators - range for open-close duty and positioning duty are rated for class A and B or types of duty S2 - 15 min. A special version for longer running is available for the S2 - 30 min duty.
- The modulating actuators of the SAR range are rated for class C or types of duty S4 - 25 %. Special versions for S4 - 50 % and S5 - 25 % are also available.
- SQ type actuators - range for open-close duty and positioning duty are rated for class A and B or types of duty S2 - 15 min.
- The modulating actuators of the SQR range are rated for class C or types of duty S4 - 25 %.
407-324-7800
Labels:
AUMA,
electric actuator,
SA,
south florida,
SQ,
wastewater treatment,
water treatment
Instrument Specialties Inc. Appointed New Exclusive Rep for AUMA Actuators in South Florida Municipal Market
AUMA, the world's leading manufacturer of electric actuators and gearboxes has appointed Instrument Specialties Inc. (ISI) as exclusive rep for the South Florida municipal (water) market. AUMA distinguishes the municipal market as sewage treatment plants, water treatment plants, drinking water distribution, sewage disposal, seawater desalination and steel constructions for water systems to operate weirs and sluice gates.
AUMA actuators are ubiquitous in the water industry due to their broad product offering which includes multi-turn, part-turn, and linear actuators, combined with a robust design that includes high corrosion protection, long service life, and low maintenance.
For more information, call 407-324-7800 of visit http://isi.group.
AUMA actuators are ubiquitous in the water industry due to their broad product offering which includes multi-turn, part-turn, and linear actuators, combined with a robust design that includes high corrosion protection, long service life, and low maintenance.
For more information, call 407-324-7800 of visit http://isi.group.
In-Situ Aqua TROLL 500
![]() |
In-Situ Aqua TROLL 500 |
With interchangeable sensors, the Aqua TROLL 500 replaces multiple instruments and saves time in the field to reduce overall monitoring costs. Highly stable sensors need minimal maintenance and calibration, giving you confidence in your data. Just plug the sonde into a Wireless TROLL Com, datalogger, control system or telemetry and you’re ready to go.
The Aqua TROLL 500 fits a wide variety of applications, including:
- Surface water spot sampling and profiling
- Remote monitoring via telemetry
- Long-term drinking water, wastewater or stormwater monitoring
- Aquaculture
- Low-flow groundwater sampling and remediation
Features
- Base sensor configuration includes: RDO Optical Dissolved Oxygen, pH/ORP, Turbidity, Conductivity, Temperature and Pressure, Salinity, resistivity, Total Dissolved Solids (TDS) and Density
- Ammonium, Chloride, and Nitrate Ion-Selective Electrode (ISE) available
- Interchangeable sensors, wet-mateable
- Sub 2” antifouling wiper cleans all sensors for higher quality data in long-term deployments
- Wireless Mobile Bluetooth® connection for Android (VuSitu app), and Win-Situ 5 for PC laptop
- Site tagging and GPS coordinates functions available via mobile app
- LCD display gives a snapshot of instruments health and wireless connectivity
- Wide sensor range for performance in a variety of applications
- Automatic environmental compensation eliminates data post-processing
- Easy integration with PLC/SCADA control systems, data loggers, and telemetry—no adapters or confusing proprietary communication protocols
- Redesigned pH and ISE reference for 3X sensor stability
- Corrosion-resistant housing and abrasion-resistant RDO sensor
- Compatible with Low-Flow system (sold separately)
407-324-7800
Webinar - The Latest on Teledyne LaserFlow, Extreme Applications - July 25
|
Happy Fourth of July from Instrument Specialties!
"America was not built on fear. America was built on courage, on imagination and an unbeatable determination to do the job at hand."
Harry S. Truman
Subscribe to:
Posts (Atom)